|
|
Connection Configuration |
Items displayed
in the
NOTE: For a single gateway, limits are 2048 connections, 10,000 doors, 100,000 inputs and 100,000 outputs.
Seven types of connections are available: Direct (RS-232 and USB), Secure IP (KT-400), Secure IP (KTES), Secure IP (IP Link), Secure IP KT-1, Ethernet (polling) and Dial-Up (RS-232) modem. Check the following table for the connection type versus the gateway.
| Connection Type | Multi-site Gateway (Note) | Global Gateway (Note) | KT-NCC (Note) |
|---|---|---|---|
| Direct (RS-232 or USB) | Yes | Yes | Yes |
| Ethernet (polling) | Yes | Yes | Yes |
| Secure IP (KT-1) | Yes | Yes | Yes |
| Secure IP (KT-400) | Yes | Yes | Yes |
| Secure IP (KTES) | Yes | ||
| Secure IP (IP Link) | Yes | ||
| Dial-up (RS-232) modem | Yes | ||
1 - From the Devices window, click the Connection button.
2 - Select a Site filter from the first drop-down list.
3 - select the Gateway.
4 - From the Connection drop-down list, select the connection where the controller is located.
5 - If you are defining a new Connection , click the New button. Assign a name to the new connection and click the Save button.
6 - Under the General tab:
• In the Hardware definition section , specify the number of controllers for the connection. There may be up to 32 controllers per connection. If the number specified is greater than the maximum allowed, the system will set the value to 32.
• Select a Time zone: This setting will allow events from the remote site to be displayed at local gateway time on EntraPass workstations located in different time zones.
• Select a Graphic and Video view to which the gateway is assigned, if applicable. The video view will only be activated If the video feature is enabled in EntraPass.
•
Use
the scroll list to select the
Connection type
| Icon | Description |
|---|---|
| KT-Standalone: selects backup files from a KT-1, firmware v2.01 and higher, and the KT-401, firmware v2.00 and higher, standalone controllers. |
Before you migrate your data, you must configure EntraPass to use the same card format, Global Card Format, and PIN length as the standalone settings:
1 - Navigate to the Account tab, and select System from the menu.
2 - To open the Display Format window, click the
3 - In the Default card format area, select the Card #1 format to match the Card #1 format in the standalone controller, repeat for Card # 2 to Card # 5.
NOTE: If card #1 and card #2 use a different display format, EntraPass migrates into card #4 or card #5.
4 - In the Global Card Format area, choose the appropriate global card format.
5 - Select the appropriate PIN length from the Number of PIN digits (KT-400 and KT-1) list.
To migrate backup data complete the following steps:
1 - On the Devices tab, select Connection from the menu.
2 - Click the KT-Standalone button on the menu bar to display the KT-standalone backup CFG files for the KT-1, firmware v2.01 and higher, and the KT-401, firmware v2.00 and higher.
3 - Select a file to see the backup information:
a - Backup date and time
b - Controller type
c - Controller MAC/Serial number
d - Controller firmware version
e - Amount of users
f - Amount of schedules
g - Amount of holidays
h - Amount of action scheduler
i - Amount of doors
j - Amount of relays
k - Amount of input
4 - A window displays with the message “Are you sure you want to import the following data?” If you click Yes: import data, the following message displays, “Migration completed”, click OK. If you click No, the message window closes.
For
more details about the Comment
entry box, please refer to